Hydric Attenuation of a Green Roof Experimental Assembly in Bogotá



Título del documento: Hydric Attenuation of a Green Roof Experimental Assembly in Bogotá
Revista: Ambiente y desarrollo (Bogotá)
Base de datos: CLASE
Número de sistema: 000434952
ISSN: 0121-7607
Autors: 1
1
2
1
Institucions: 1Pontificia Universidad Javeriana, Departamento de Ingeniería Civil, Medellín, Antioquia. Colombia
2Pontificia Universidad Javeriana, Departamento de Ecología y Territorio, Medellín, Antioquia. Colombia
Any:
Període: Ene-Jun
Volum: 20
Número: 38
Paginació: 53-68
País: Colombia
Idioma: Inglés
Tipo de documento: Artículo
Enfoque: Analítico, descriptivo
Resumen en español En este estudio se evaluó la atenuación hídrica de un techo verde utilizando tres indicadores: lag-time, coeficiente de escorrentía y volumen de agua retenida. Se registraron siete eventos de lluvia y se evaluó su respuesta para dos tipos de plantas —Pennisetum clandestinum y Melissa officinalis— y tres profundidades de sustrato (5, 10 y 15 cm), para un total de seis tratamientos con tres repeticiones. Los experimentos se realizaron en el techo del edificio “Rafael Arboleda” de la Pontificia Universidad Javeriana, Bogotá Colombia (4°37’43 .33’’, 74 º 03’46 .04 ‘’) a 2633 metros sobre el nivel del mar. Máximos lag-time y coeficientes de escorrentía de 70 minutos y 0,1, respectivamente. De la misma manera, se observaron volúmenes de retención máximos cercanos al 100%. Sin embargo, se evidenciaron variabilidades importantes de estos resultados, los cuales se analizaron utilizando el análisis de correspondencias múltiples y Anova: el tipo de planta y las características hidrológicas del evento de lluvia (duración, intensidad máxima, intensidad media, nivel de drenado) tienen influencias significativas sobre estas variabilidades
Resumen en inglés In this study, the hydric attenuation of a green roof was assessed by using three indicators: lag-time, runoff coefficient, and water volume retention. Two types of plants —Pennisetum clandestinum and Melissa officinalis— and three substrate depths (5, 10, and 15 cm) for a total of 6 treatments with three replicates and seven rain events were registered. The experiments were carried on the top roof of the “Rafael Arboleda” building from Pontificia Universidad Javeriana, Bogotá Colombia (4 ° 37’43 .33’’, 74 º 03’46 .04’’) at 2633 meters above sea level. Maximum lagtimes and runoff equivalent ratios of 70 minutes and 0.1 respectively, as well as a maximum volumetric percentage retention close to 100% were obtained. However, important variabilities of these results were observed, which were analyzed by using multiple correspondence analysis and Anova: the type of plant and hydrological characteristics of the rainfall event (duration, maximum intensity, mean intensity, level drained) have significant influence on these variabilities
Otro resumen Dans cette étude on a évalué l’atténuation hydrique d’un plafond vert en utilisant trois indicateurs : lag-time, coefficient du ruissellement et volume d’eau capté. On registré sept évènements de pluie et on a évalué la réponse pour deux types de plants —Pennisetum clandestinum y Melissa officinalis— et trois profondeurs de substrat (5, 10 y 15 cm), au total de six traitements avec trois répétitions. Les expérimentés ont étés réalisés dans le plafond du bâtiment « Rafael Arboleda» de la Pontificia Universidad Javeriana, Bogotá Colombie (4°37’43 .33’’, 74 º 03’46 .04 ‘’) à 2633 mètres au-dessus du niveau de la mer. Maximal lag-time et coefficient de ruissellement de 70 minutes et 0,1, respectivement. De la même façon on a observé volumes de captation maximaux proches au 100%. Cependant, on a observé changements importants de ces résultats, ceux-ci ont étés analysés en utilisant l’analyse de correspondances multiples y Anova : le type de plante et les caractéristiques hydrologiques de l’évènement de pluie (durée, intensité maximal, intensité moyenne, niveau de drainage) ont influences importantes sur ces variables
Disciplines Geociencias
Paraules clau: Hidrología,
Inundaciones,
Escorrentía,
Techo verde,
Estimadores Kernel
Text complet: Texto completo (Ver PDF)