The hemodynamic response to acoustically modified syllables in premature and full term newborn infants acquired by near infrared spectroscopy



Título del documento: The hemodynamic response to acoustically modified syllables in premature and full term newborn infants acquired by near infrared spectroscopy
Revista: Acta Colombiana de Psicología
Base de datos: CLASE
Número de sistema: 000532030
ISSN: 0123-9155
Autors: 1
1
1
2
1
Institucions: 1Universidad Nacional Autónoma de México, Instituto de Neurobiología, Querétaro. México
2Centro de Investigación en Matemáticas A.C., Guanajuato. México
Any:
Període: Jul-Dic
Volum: 17
Número: 2
Paginació: 13-21
País: Colombia
Idioma: Inglés
Tipo de documento: Artículo
Enfoque: Analítico
Resumen en español Esta investigación evalúa, en neonatos, la respuesta hemodinámica ante sílabas modificadas acústicamente (pronunciadas de manera prolongada) en comparación con la respuesta a sílabas no modificadas (pronunciadas a una velocidad normal). El objetivo fue evaluar cuál de estas condiciones de estimulación producía una mejor discriminación silábica en dos grupos de neonatos: 13 prematuros (edad gestacional promedio de 30 semanas, DE 3 semanas) y 13 nacidos a término (edad gestacional promedio de 38 semanas, DE 1 semana). La discriminación de sílabas, en cada condición, se evaluó mediante un paradigma oddball (ensayos con sílabas iguales vs. ensayos con sílaba diferente). El análisis estadístico se basó en la comparación de la respuesta hemodinámica [oxyHb] obtenida por espectroscopia de infrarrojo cercano (NIRS) ante ensayos con sílabas iguales Vs. ensayos con una sílaba diferente en cada condición. Se encontró que la condición de sílabas modificadas obtuvo mejores resultados para la discriminación entre ensayos en ambos grupos. La amplitud de la respuesta hemodinámica ante el ensayo con una sílaba diferente fue significativamente mayor que ante el ensayo con sílabas iguales: en recién nacidos a término, t = 2,59, p = 0,024 y en los prematuros, t = 2,38, p = 0,035. Este hallazgo ocurrió en el lóbulo temporal izquierdo. Estos datos sugieren que las sílabas modificadas facilitan el procesamiento de fonemas desde el nacimiento
Resumen en inglés This research assesses, in newborns, the hemodynamic response to acoustically modified syllables (pronounced in a prolonged manner), versus the response to unmodified syllables (pronounced at a normal rate). The aim was to assess which of these stimulation conditions produced better syllable discrimination in two groups of neonates: 13 preterm (mean gestational age 30 weeks, SD 3 weeks), and 13 full term newborns (mean age 38 weeks, SD 1 week). Syllable discrimination, in each condition, was assessed by using an oddball paradigm (equal syllable trials vs. different syllable trials). The statistical analysis was based on the comparison between the hemodynamic response [oxyHbO] obtained by Near Infrared Spectroscopy (NIRS) to different syllable trials vs. equal syllable trials, in each condition. The modified syllable condition was better in producing trial discrimination in both groups. The amplitude of the hemodynamic response to the different syllable trials was greater than the one to the equal syllable trials: for term infants, t = 2.59, p = 0.024, and for preterm t = 2.38, p = 0.035. This finding occurred in the left temporal lobe. These data suggest that the modified syllables facilitate processing of phonemes from birth
Resumen en portugués Esta pesquisa avalia, em neonatos, a resposta hemodinâmica diante sílabas modificadas acusticamente (pronunciadas de maneira prolongada) em comparação com a resposta a sílabas não modificadas (pronunciadas a uma velocidade normal). O objetivo foi avaliar qual destas condições de estimulação produzia uma melhor discriminação silábica em dois grupos de neonatos: 13 prematuros (idade gestacional média de 30 semanas, DE 3 semanas) e 13 nascidos a termo (idade gestacional média de 38 semanas, DE 1 semana). A discriminação de sílabas, em cada condição, foi avaliada mediante um paradigma oddball (ensaios com sílabas iguais vs. ensaios com sílaba diferente). A análise estadística se baseou na comparação da resposta hemodinâmica [oxyHb] obtida por espectroscopia de infravermelho próximo (NIRS) ante ensaios com sílabas iguais Vs. ensaios com uma sílaba diferente em cada condição. Encontrou-se que a condição de sílabas modificadas obteve melhores resultados para a discriminação entre ensaios em ambos os grupos. A amplitude da resposta hemodinâmica ante o ensaio com uma sílaba diferente foi significativamente maior que perante o ensaio com sílabas iguais: em recém-nascidos a termo, t = 2,59, p = 0,024 e nos prematuros, t = 2,38, p = 0,035. Este descobrimento ocorreu no lóbulo temporal esquerdo. Estes dados sugerem que as sílabas modificadas facilitam o processamento de fonemas desde o nascimento
Disciplines Psicología
Paraules clau: Desarrollo psicológico,
Lingüística aplicada,
México,
Prematuros,
Neonatos,
Adquisición del lenguaje,
Habla modificada acústicamente,
Procesamiento auditivo temporal,
Espectroscopia del infrarrojo cercano
Keyword: Developmental psychology,
Applied linguistics,
Mexico,
Preterm neonates,
Language acquisition,
Acoustically modified syllables,
Auditory temporal processing,
Near Infrared Spectroscopy
Text complet: Texto completo (Ver HTML) Texto completo (Ver PDF)