Estudio comparativo de dos métodos para la determinación de autoanticuerpos en hepatitis autoinmune



Document title: Estudio comparativo de dos métodos para la determinación de autoanticuerpos en hepatitis autoinmune
Journal: Acta bioquímica clínica latinoamericana
Database: PERIÓDICA
System number: 000424095
ISSN: 0325-2957
Authors: 1
1
1
1
1
Institutions: 1Universidad Autónoma de Nuevo León, Facultad de Medicina, Monterrey, Nuevo León. México
Year:
Season: Dic
Volumen: 48
Number: 4
Pages: 403-408
Country: Argentina
Language: Español
Document type: Artículo
Approach: Experimental, aplicado
Spanish abstract La hepatitis autoinmune es una inflamación hepatocelular que se caracteriza por diversos autoanticuerpos circulantes. En el presente trabajo se evaluó la concordancia entre los resultados obtenidos por la técnica ELISA y por la técnica de inmunofluorescencia indirecta (IFI) para la determinación de autoanticuerpos en hepatitis autoinmune. Se incluyeron 123 pacientes con hepatitis autoinmune, 91 (74%) del sexo femenino y 32 (26%) de sexo masculino, mayores de 18 años, en los cuales se realizó un estudio comparativo entre ELISA e inmunofluorescencia indirecta para la detección de los anticuerpos antinucleares (78 pacientes), anticuerpos antimitocondriales (84 pacientes) y antimicrosoma hepatorrenal (85 pacientes). De acuerdo al valor kappa obtenido se encontró que para el anticuerpo antimicrosoma hepatorrenal el nivel de concordancia fue muy bueno (k=1,0, p<0,001); para el anticuerpo antinuclear el nivel de concordancia fue débil, sin embargo fue significativo (k=0,37, p<0,001) mientras que para el anticuerpo antimitocondrial el nivel de concordancia fue pobre (k=0,05, p<0,476). La determinación del anticuerpo antimicrosoma hepatorrenal fue la prueba con mayor sensibilidad, especificidad y concordancia entre ambas técnicas analizadas y se estableció que la técnica de ELISA para el anticuerpo antimitocondrial solo concuerda con la técnica de inmunofluorescencia indirecta en sujetos con títulos altos
English abstract Autoimmune hepatitis is a hepatocellular inflammation which is characterized by different circulating autoantibodies. In this paper, the correlation between the results obtained by ELISA and indirect immunofluorescence technique for the determination of autoantibodies in autoimmune hepatitis was evaluated. One hundred and twenty-three patients with autoimmune hepatitis, 91 (74%) female and 32 (26%) male, over 18 years were included. In these patients, a comparative study between ELISA and indirect immunofluorescence detection of the antinuclear antibodies (78 patients), anti-mitochondrial antibodies (84 patients) and anti-liver kidney microsome (85 patients) was performed. According to the kappa value obtained, it was found that for anti-liver kidney microsome the level of agreement was very good (k=1.0, p<0.001) for antinuclear antibody, the level of concordance was weak but significant (k=0.37, p<0.001,) meanwhile antimitochondrial antibody level of concordance was poor (k=0.05, p<0.476).The determination of the antibody anti-liver kidney microsome was the test with greater sensitivity, specificity and concordance between the two techniques discussed and it was established that the ELISA technique for antimitochondrial antibody is only in concordance with the indirect immunofluorescence in patients with high titers
Portuguese abstract A hepatite autoimune é uma inflamação hepatocelular, que se caracteriza pelos diferentes anticorpos circulantes. Neste trabalho foi avaliada a correlação entre os resultados obtidos através da técnica ELISA e da técnica de imunofluorescência indireta (IFI) para a determinação de auto-anticorpos na hepatite auto-imune. Foram incluídos 123 pacientes com hepatite autoimune, 91 (74%) do sexo feminino e 32 (26%) do sexo masculino, maiores de 18 anos, nos quais foi realizado um estudo comparativo entre ELISA e Imunofluoresência Indireta para a detecção dos anticorpos antinucleares (78 pacientes), anticorpos antimitocondriais (84 pacientes) e antimicrossomal hepatorrenal (85 pacientes). De acordo ao valor kappa obtido, foi encontrado que para o anticorpo antimicrossomal hepatorrenal o nivel de concordância foi muito bom (k=1,0, p<0,001); para o anticorpo antinuclear o nivel de concordância foi fraco, porém foi significativo (k=0,37, p<0,001) enquanto que para o anticorpo antimitocondrial o nivel de concordância foi pobre (k=0,05, p<0,476). A determinação do anticorpo antimicrossomal hepatorrenal foi o teste com maior sensibilidade, especificidade e concordância entre ambas técnicas analisadas e se estabeleceu que a técnica de ELISA, para o anticorpo antimitocondrial, só concorda com a técnica de Imunofluorescência Indireta em sujeitos com títulos altos
Disciplines: Química
Keyword: Bioquímica,
Anticuerpos,
Hepatitis autoinmune,
ELISA,
Inmunofluorescencia indirecta
Keyword: Biochemistry,
Antibodies,
Autoimmune hepatitis,
Indirect immunofluorescence
Full text: Texto completo (Ver PDF)