Approach: Aplicado, descriptivo
Spanish abstract El estudio se realizó con el fin de comparar el comportamiento térmico de los diferentes tipos de tejas mediante la medición de la temperatura de la superficie externa (EST) y la temperatura de la superficie interna (IST) durante el día. El diseño experimental fue completamente al azar, compuesto por 5 tratamientos: AC– Asbesto Cemento; BA–Bambú; BAP– Bambú Pintado de Blanco; FB– fibra vegetal y betún; FBP– fibra vegetal y betún pintado de Blanco, con 15 repeticiones, siendo considerados como repeticiones los días de medición. Fueron registradas las temperaturas de la superficie interior y de la superficie exterior de las tejas, a las 8:00 am, 10:00 am, 12:00 pm, 2:00 pm, 4:00 pm y 6:00 pm. Los datos fueron analizados por el programa SISVAR 5.1®, mediante el análisis de varianza y la prueba de Scott Knott para la comparación de medias, el nivel de significación del 1%. FB tuvo el peor desempeño térmico cuando se compara con las otras tejas, con mejor resultado para BAP
English abstract This study was developed in order to compare the thermal behavior of different types of roofs by measuring the External Surface Temperature (EST) and the Internal Surface Temperature (IST) over the days. The experimental design was completely randomized, with five treatments: AC - Asbestos cement tiles, BA -Bamboo tiles, BAP - Bamboo tiles painted in white, FB -Vegetable fiber tiles and bitumen, FBP -Vegetable fiber tiles and bitumen painted in white, with 15 repetitions, being adopted as repetitions the days of measurement. The temperature of the internal and external roofing surfaces was collected at 8:00 am, 10:00 am, 12:00 pm, 2:00 pm, 4:00 pm and 6:00 pm. Data were analyzed by SISVAR 5.1® program through the analysis of variance and Skott Knott test for comparison of means, significance level at 1%. The FB coverage showed the worst thermal performance compared to other types of coverage, with the best results observed in BAP coverage